I've seriously lost count of how many have failed on me over the years - they are consumables, really. Why does Ubuntu 16.04 installation create an extended partition besides the swap? share|improve this answer answered Nov 20 '11 at 15:33 Sven♦ 66k8103145 add a comment| Your Answer draft saved draft discarded Sign up or log in Sign up using Google Sign If it is, you repair the error, continue the rebuild, and then replace disk p5 and rebuild again. have a peek here

One other reason for this problem could be a virus attack so acquiring a good anti-virus is also a good thing. Post navigation Previous PostAdobe Illustrator Cs6 Error Loading PluginsNext PostLoan Prospector Error Code 64 Search for: Proudly powered by WordPress főoldal blogok fórumok szavazások HupWiki ls -1 /boot Is a north-facing window recommended outside of the northern hemisphere? This has been happening for a week now, and I can't rebuild the array. http://serverfault.com/questions/574428/issue-rebuilding-raid5-with-3ware-controller

3ware Ecc Error

more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Science október 26., hétfő - 12:42 ) WD jó választásnak tűnik. The p5 disk throws DEVICE-ERROR and stops the rebuild process. Why TensorFlow can't fit simple linear model if I am minimizing absolute mean error instead of the mean squared error?

QGIS invalid vertices Official Bank Check Are human fetal cells used to produce Pepsi? Szóval az alábbit kell tennem: 1. An installation procedure is needed if it’s a software that causes the problem. Tw_cli Start Rebuild Assuming that's not enough, the best approach at this point is to copy off the data from the array (or restore from backups).

First, take the drive offline by issuing a 'remove' command. 3ware Degraded Drive A hozzászóláshoz belépés szükséges permalink Keresés

Navigáció friss tartalom hírolvasó Belépés Felhasználói név: * Jelszó: * Elfelejtett jelszó HupWiki AIX FAQ Lazarus AIX FAQ tovább Állásajánlatok NNG - Online Product All four drives are flashing a lot, that's a good sign, right? –Bill Weiss Nov 20 '11 at 17:19 Stiiiiiil rebuilding... http://www.brumster.com/articles.php?article_id=8 There are also some options to ignore ECC errors during rebuild: /cx/ux start rebuild disk=p [ignoreECC] /cx/ux set ignoreECC=on|off However, using these options means that the RAID stripe affected by a

Bummer. –Bill Weiss Nov 20 '11 at 17:07 1 AFAIR, the drive is kept marked as DEGRADED during the rebuild — see, e.g., here. Tw_cli Stop Rebuild The best thing to do is open the computer in safe mode so that you could uninstall the software recently added, also remove any hardware devices attached to it. Tapasztalat. :( A hozzászóláshoz belépés szükséges permalink ( topi | 2009. Mert ha nem, nem fog menni. (Bár, ha csak 2 portos a kártya, más választásod HW beruházás nélkül nem lesz.) A hozzászóláshoz belépés szükséges permalink ( topi | 2009.

3ware Degraded Drive

Is there any way to ignore this DEVICE-ERROR just until the array is rebuilt? http://tomdownload.net/software/3ware-9650se-device-error/ I'll speculate that the guy who set this up turned that off for performance reasons :( –Bill Weiss Nov 24 '11 at 3:41 Well, that got it through the 3ware Ecc Error Not looking great for my data. –Bill Weiss Nov 24 '11 at 3:40 1 And, yeah, we should let the arrays verify from time to time. Tw_cli U? What are the best old electrical appliances to extract electronic components from?

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed navigate here Based on your updated information, you're probably out of luck with regards to repairing this array. Issue a rescan command, and the controller will scan the ports and detect the newly-installed drive... //server1/c6> rescan Next we are ready to start the array rebuilding with the Related 23Ware 9650SE is rebuilding RAID6 array with two degraded disks?2Rebuilding array on 3ware 9690SA-8I53Ware 9650SE RAID-6, two degraded drives, one ECC, rebuild stuck03ware raid controller, unit unusable, several degraded disks53Ware Ecc Error 3ware Raid

If a subsequent disk fails in unit u0, this disk will automatically get assigned to the array and an autorebuild started (assuming you've got auto-rebuild enabled of course). //server1/c6> share|improve this answer edited Feb 10 '14 at 11:51 answered Feb 10 '14 at 11:25 HopelessN00b 44.6k1799168 If i replace the p5 disk which throws DEVICE-ERROR, I will lose I would try to copy the data off somewhere (and I'm betting some of it will be corrupted /lost - the data you're getting a DEVICE-ERROR from P5 on), and then Check This Out The new unit is /c6/u1.WARNING: This Spare unit may replace failed drive of same interface type only.//server1/c6> showUnit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy------------------------------------------------------------------------------u0 RAID-5 REBUILDING 36% - 256K

október 26., hétfő - 13:13 ) Sokkal nagyobb sajnos. 650GB. Hard Drive Ecc Error Re-installing the operating system will be a quick move to stabilize your computer. Amúgy nekem eddig nem volt gondom samsung+3ware párossal.

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed

Ez a DEVICE-ERROR csak valami flag? Why is nuclear waste more dangerous than the original nuclear fuel? It is in fact rebuilding... 3ware Degraded Ecc-error It will also be a benefit to you as you will get more knowledge in the technicality of computers, especially that you're utilizing it daily.

sudo tw_cli Then issue a show command to list the controllers installed and detected... //server1> showCtl Model (V)Ports Drives Units NotOpt RRate VRate BBU------------------------------------------------------------------------c6 9590SE-8ML 8 5 1 This might be possible because the controller doesn't know if it lost data or just an empty area (it lacks any insight into the file system). Done. и видим, что диск успешно удалился srvxxx:~# tw_cli info c2 Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy ------------------------------------------------------------------------------ u0 RAID-1 DEGRADED - - - 372.519 OFF ON Port http://theblackinkproject.com/ecc-error/3ware-error.html A hozzászóláshoz belépés szükséges permalink ( STP | 2009.

So a disk goes AWOL and your RAID5 array is degraded; what do you do? Different RAID settings for different folders on the same logical drive Would this be considered as plagiarism? Vagy mit is kell tennem ilyenkor? raid controller share|improve this question edited Feb 10 '14 at 12:11 HopelessN00b 44.6k1799168 asked Feb 10 '14 at 11:21 Alex Angelov 11 RAID is not backup, it just reduces

It stays at 97% rebuilt, but can't get past this error. Do n and n^3 have the same set of digits? Lock a table on purpose without returning results The meaning of "span" that belongs to horses Clash between tcolorbox and amsfonts How to create a macro that creates other macros (that kid in winter Countries where lecture duration does not exceed one hour Should I have doubts if the organizers of a workshop ask me to sign a behavior agreement upfront?

This saves you specifying "c4" in front of every command. Alphabetically permute a string How would corporations look like if the conglomerates are banned? maybe not? If you haven't a backup, you can try to dump the current state of the array.